Server Room Raised Floor Height

Their placement onto the raised access floor should be planned and managed.
Server room raised floor height. They don t adjust easily to curved or angular walls and must be cut to fit the room perimeter. For computer room raised access floors and or non ground floor basement areas it is important to check the floor loading to ensure the the floor structure can support the weight of the server rack or ups system to be placed upon it. When used as an exhaust space refer to vdi 2054 for the floor room air conditioning system standard for floor height. Floor loadings are measured in kn m.
Standard heights are usually 12 or more with some floors reaching 6 feet or higher. 200 500 square meters about 400 mm. Most loads placed onto a raised access floor will be static and rarely if ever moved except as part of a swap out or replacement program. This false floor is commonly use in datacenter server room telecom rooms.
Traditional post and panel raised floors lack flexibility. These floors allow under floor cable management as well as airflow. And because of their height they can require up to four feet to transition down to another room without a raised floor. A three phase 100kva ups with a 5m battery can have a total weight of 1200kg or 1 2tonnes.
The raised floor is constructed of 600x600mm anti static floor tiles to the information room with a height of at least 300mm. A standard traditional access floor is anything higher than 6. For easy access raised floor solutions need panels that can be easily removed for access to cables cooling and power below. Depending on data center size and the amount of equipment that needs to be cooled a raised floor in today s world should be at least 18 inches high preferably 24 30 inches to hold the necessary cable bundles without impeding the high volumes of air flow needed to cool modern technology.
Required raised floor height for data center. In general raised server room floors are a predictable and practical design option for most facilities. Also once installed it s a rigid system. Such flooring can be installed at varying heights from 2 inches 51 mm to heights above 4 feet 1 200 mm to suit services that may be accommodated beneath.
Additional structural support and lighting are often provided when a floor is raised enough for a person to crawl or even walk beneath. Increased finished floor system heights for additional services and temperature control normal 300mm 800mm. Ups systems and server cabinets are typical examples of hardware systems that will sit inside a server room. It is also called as access floor or raised access floor.
Raised floor is physical structure made up of square shape movable tiles which supported by height adjustable legs called pedestal and which constitute parallel floor between room floor and room roof to create service area.